Functional reliability assessment of marine electrical systems and energy efficiency opportunities: A case study of KMP Sebuku
Politeknik Pelayaran Banten
Politeknik Pelayaran Banten
Politeknik Pelayaran Banten
Politeknik Pelayaran Banten
Politeknik Pelayaran Banten
DOI:
https://doi.org/10.62391/ejmi.v8i2.317Penelitian ini mengevaluasi keandalan fungsional sistem kelistrikan, pemantauan main switchboard (MSB), dan peluang efisiensi energi pada KMP Sebuku, kapal Ro-Ro yang melayani Merak–Bakauheni. Studi kasus kualitatif deskriptif ini menganalisis satu catatan observasi teknis tanggal 26 Agustus 2026, tanpa pengukuran tambahan melalui klasifikasi kondisi peralatan, interpretasi risiko, dan penyusunan prioritas perbaikan. Riwayat operasi yang dilaporkan tidak mencatat blackout, tetapi layar power meter digital MSB tidak menampilkan informasi, sementara meter analog masih berfungsi. Temuan lain mencakup catu daya tambahan, pengendali wiper yang tidak berfungsi, pengaturan penerangan manual, dan penggunaan lampu fluoresen. Simulasi penggantian lampu 36 W menjadi 16 W menunjukkan pengurangan daya 20 W per titik atau 55,6% pada beban lampu tersebut; penghematan aktual kapal belum terukur. Penelitian merekomendasikan diagnosis bertahap, verifikasi fungsi keselamatan, penataan instalasi, pemeliharaan berbasis kondisi, dan audit energi sebelum retrofit.
This study evaluates the functional reliability of marine electrical systems, main switchboard (MSB) monitoring, and energy-efficiency opportunities aboard KMP Sebuku, a Ro-Ro ferry operating on the Merak–Bakauheni route. A descriptive qualitative case-study design was applied to a single technical observation record dated 26 August 2026, without additional measurements. Evidence was classified by equipment condition, functional consequence, verification needs, and corrective-action priority. The reported operating history contained no blackout incidents; nevertheless, the MSB digital power-meter display was blank while analog instruments remained functional. Other findings included supplementary power supplies, a nonfunctional digital wiper controller, manual lighting selection, and extensive fluorescent lighting. An illustrative conversion from 36 W fluorescent lamps to 16 W LEDs yields a nominal reduction of 20 W per lamp (55.6% of the original lamp load), but vessel-wide savings were not measured. The study recommends sequential fault diagnosis, verification of safety-related auxiliary functions, installation inspection, condition-based maintenance, and an instrumented energy baseline before retrofit decisions. Findings distinguish documented observations from hypotheses requiring further tests.
Keywords: electrical reliability energy efficiency ferry main switchboard maintenance
Barros, J., & Diego, R. I. (2016). A review of measurement and analysis of electric power quality on shipboard power system networks. Renewable and Sustainable Energy Reviews, 62, 665–672. https://doi.org/10.1016/j.rser.2016.05.043
Tarasiuk, T., Jayasinghe, S. G., Gorniak, M., Pilat, A., Shagar, V., Liu, W., & Guerrero, J. M. (2021). Review of power quality issues in maritime microgrids. IEEE Access. https://doi.org/10.1109/ACCESS.2021.3086000
Mindykowski, J., Tarasiuk, T., & Gnaciński, P. (2021). Review of legal aspects of electrical power quality in ship systems in the wake of the novelisation and implementation of IACS rules and requirement. Energies, 14(11), 3151. https://doi.org/10.3390/en14113151
International Maritime Organization. (1974, as amended). International Convention for the safety of life at Sea (SOLAS), chapter II-1. IMO.
International Maritime Organization. (2018). International Safety Management (ISM) Code and guidelines on implementation. IMO.
Zohrabi, N., Shi, J., & Abdelwahed, S. (2019). An overview of design specifications and requirements for the MVDC shipboard power system. International Journal of Electrical Power & Energy Systems, 104, 680–693. https://doi.org/10.1016/j.ijepes.2018.07.050
van der Sande, R., Shekhar, A., & Bauer, P. (2025). Reliable DC shipboard power systems—Design, assessment, and improvement. IEEE Open Journal of the Industrial Electronics Society, 6, 235–264. https://doi.org/10.1109/OJIES.2025.3532095
KMP Sebuku Research Team. (2026). Applied technical observation report on the electrical systems of KMP Sebuku (26 August 2026) [Unpublished internal technical record].
Huang, K., Li, W., Cao, S., Gao, F., Li, R., Xu, W., & Lin, B. (2026). Recent advances in fault diagnosis of ship integrated power systems: A review. Ocean Engineering. https://doi.org/10.1016/j.oceaneng.2025.123141
International Organization for Standardization. (2018). ISO 50001:2018 energy management systems—Requirements with guidance for use. ISO.
Al-Falahi, M. D. A., Tarasiuk, T., Jayasinghe, S. G., Jin, Z., Enshaei, H., & Guerrero, J. M. (2018). AC ship microgrids: Control and power management optimization. Energies, 11(6), 1458. https://doi.org/10.3390/en11061458
Hüffmeier, J., & Johanson, M. (2021). State-of-the-art methods to improve energy efficiency of ships. Journal of Marine Science and Engineering, 9(4), 447. https://doi.org/10.3390/jmse9040447
Institute of Electrical and Electronics Engineers. (2013). IEEE Std 43-2013: IEEE recommended practice for testing insulation resistance of electric machinery. IEEE.
Karatuğ, Ç., & Arslanoğlu, Y. (2022). Development of condition-based maintenance strategy for fault diagnosis for ship engine systems. Ocean Engineering, 256, 111515. https://doi.org/10.1016/j.oceaneng.2022.111515
Ma, R., Zhao, Q., Wang, K., Cao, J., Yang, C., Hu, Z., & Huang, L. (2025). Energy efficiency improvement technologies for ship in operation: A comprehensive review. Ocean Engineering, 331, 121258. https://doi.org/10.1016/j.oceaneng.2025.121258
Fang, S., & Xu, Y.. (2020). Multi-objective robust energy management for all-electric shipboard microgrid under uncertain wind and wave. International Journal of Electrical Power & Energy Systems. https://doi.org/10.1016/j.ijepes.2019.105600
Jung, J., Jeon, H., & Kim, J.. (2026). Grid risk index-based safety margin assessment for hybrid electric shipboard power systems. International Journal of Electrical Power & Energy Systems. https://doi.org/10.1016/j.ijepes.2026.112229
Billah Kushal, T. R., & Illindala, M. S.. (2020). Correlation-based feature selection for resilience analysis of MVDC shipboard power system. International Journal of Electrical Power & Energy Systems. https://doi.org/10.1016/j.ijepes.2019.105742
Ding, Y., Ma, S., Liu, G., Sui, C., & Xiang, L.. (2025). Optimization of sizing and energy management in hybrid energy storage systems for transient suppression in ship power systems under adverse sea conditions. International Journal of Electrical Power & Energy Systems. https://doi.org/10.1016/j.ijepes.2025.110864
Liu, S., Sun, Y., Zhang, L., & Su, P.. (2021). Fault diagnosis of shipboard medium-voltage DC power system based on machine learning. International Journal of Electrical Power & Energy Systems. https://doi.org/10.1016/j.ijepes.2020.106399
Kim, K. O., & Zuo, M. J.. (2018). General model for the risk priority number in failure mode and effects analysis. Reliability Engineering & System Safety. https://doi.org/10.1016/j.ress.2017.09.010
Zheng, H., & Tang, Y.. (2020). Deng entropy weighted risk priority number model for failure mode and effects analysis. Entropy. https://doi.org/10.3390/e22030280
Bhattacharjee, P., Dey, V., & Mandal, U. K.. (2020). Risk assessment by failure mode and effects analysis (FMEA) using an interval number based logistic regression model. Safety Science. https://doi.org/10.1016/j.ssci.2020.104967
Tang, Y., Zhou, D., & Chan, F. T. S.. (2018). AMWRPN: Ambiguity measure weighted risk priority number model for failure mode and effects analysis. IEEE Access. https://doi.org/10.1109/access.2018.2836139
International Electrotechnical Commission. (n.d.). IEC 60092 series: Electrical installations in ships. IEC.
Ahn, J., Lee, S., Jeong, J., & Choi, Y. (2021). Comparative feasibility study of combined cycles for marine power system in a large container ship considering energy efficiency design index (EEDI). International Journal of Hydrogen Energy. https://doi.org/10.1016/j.ijhydene.2021.07.068
Tsoumpris, C., & Theotokatos, G. (2023). A decision-making approach for the health-aware energy management of ship hybrid power plants. Reliability Engineering & System Safety. https://doi.org/10.1016/j.ress.2023.109263
Xu, L., Wen, Y., Luo, X., Lu, Z., & Guan, X. (2022). A modified power management algorithm with energy efficiency and GHG emissions limitation for hybrid power ship system. Applied Energy. https://doi.org/10.1016/j.apenergy.2022.119114
Stevens, B., Dubey, A., & Santoso, S. (2015). On improving reliability of shipboard power system. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2014.2354638
Li, Y., Ding, Z., Yu, Y., & Liu, Y. (2023). Hierarchical control of hybrid energy storage system in shipboard gas turbine power system with multiple pulsed power loads. Energy Reports. https://doi.org/10.1016/j.egyr.2023.05.144
Lai, K., & Illindala, M. S. (2018). A distributed energy management strategy for resilient shipboard power system. Applied Energy. https://doi.org/10.1016/j.apenergy.2018.06.111
Hester, P., Thomas, L., & Mahadevan, S. (2005). Reliability-Based shipboard facility optimization. Journal of Ship Production. https://doi.org/10.5957/jsp.2005.21.4.235
Lan, H., Xiao, Y. Y., & Zhang, L. J. (2010). Multi-agent system optimized reconfiguration of shipboard power system. Journal of Marine Science and Application. https://doi.org/10.1007/s11804-010-1017-2
Lan, H., Li, J. F., & Zhang, D. H. (2010). Power flow calculation method of large shipboard power system. Journal of Marine Science and Application. https://doi.org/10.1007/s11804-010-8088-y